Float Level Transmitter

Float Level Transmitter

Float Level Transmitter

Float Operated Level Transmitters are designed for continuous and reliable measurement of liquid levels in tanks containing corrosive or non-corrosive liquids. The system consists of a non-magnetic sealed stem with a series of reed switches and resistors, a magnetic float, mounting flange, and an electronic circuit housed in a weatherproof or flameproof enclosure.

As the liquid level rises or falls, the magnetic float moves along the stem, actuating reed switches and generating a proportional voltage signal. This is converted into a standard 4–20 mA output compatible with PLC, DCS, remote display units, or integral indicators. It is a proven and accurate solution for a wide variety of industrial applications.

Product Share on :

Applications

  • Storage and process tanks
  • Water, diesel, oils & lube oils
  • Chemical & petrochemical liquids
  • Acids: Nitric Acid, 98% H₂SO₄, 33% HCL
  • Critical inventory & pressurized vessels
  • Interface level applications
  • WTPs, STPs & ETPs
  • Nuclear power plants
  • Tank gauging systems for ships

Construction & Working

The transmitter features a sealed, non-magnetic stem equipped with reed switches and resistors, a float containing a permanently magnet, and a flange for mounting. The float moves with the liquid level, actuating reed switches that generate a proportional voltage. This signal is processed by the transmitter electronics to provide a 4–20 mA output. The design ensures accurate, stable, and repeatable measurement for a wide variety of industrial liquids.

Key Features

  • Easy installation with compact design
  • Factory calibrated – ready for installation
  • Customized stem lengths up to 3 meters
  • Optional HART or RS-485 MODBUS output
  • Accurate and reliable performance
  • Weatherproof or flameproof enclosures available

Technical Specifications

Level Transmitter Type Float Level Transmitter
Max. Stem Length 0.5 to 3 meters
Measuring Range Stem Length – (Top Dead Band + Bottom Dead Band)
Installation Top
Resolution ±10 mm (Standard), ±5 mm (Optional)
Enclosure Cast Aluminium – Weatherproof / Flameproof
Cable Entry PG11 or ½” NPT
Wetted Parts SS304 / SS316 / SS316L / PP / PVDF
Float Options SS316 (Ø40, Ø52), SS316L (Ø41), PP (Ø75), PVDF (Ø65)
Liquid Specific Gravity 0.8 to 1.2 (depending on float size)
Process Connection Screwed / Flanged / Triclover Ferrule
Power Supply 24 VDC
Output 4–20 mA (2-wire) / 4–20 mA + HART / RS-485 MODBUS
Max. Load 400 Ohms
Max. Temperature 70°C (PP), 100°C (PVDF), 150°C (SS)
Max. Test Pressure 2 Bar (PP/PVDF), 10 Bar (SS)

Model Identification

  • FLT – Base Model
  • 1. Stem Length: In mm
  • 2. Resolution: 10 = ±10 mm, 5 = ±5 mm
  • 3. Enclosure: W – Weatherproof, F – Flameproof
  • 4. Wetted Parts: 4 – SS304, 6 – SS316, L – SS316L, P – PP, D – PVDF, O – Other
  • 5. Process Connection Size: D – 2”, E – 2½”, F – 3”, O – Other
  • 6. Process Connection Type: 1 – ASME 150#, 2 – Table D, 3 – BSP(M), 4 – Triclover, 0 – Other
  • 7. Process Connection Material: H – CS, I – SS304, J – SS316, K – SS316L, L – PP Cladding, M – PVDF, O – Other
  • 8. Output: 1 – 4–20 mA, 2 – 4–20 mA with HART, 3 – RS-485 MODBUS RTU
whatsapp whatsapp